Applications
High-containment animal biosafety laboratories (ABSL-2/3), animal experimental facilities, veterinary research institutions, and locations requiring airtight transfer of experimental animals, cages or materials between isolated zones.
Customer Requirements
- Airtight transfer of experimental animals, cages and materials between contaminated and clean zones;
- Prevention of pathogenic aerosol escape during material exchange;
- Maintenance of stable pressure differential isolation between biosafety zones;
- Corrosion-resistant, easy-to-clean materials suited to long-term high-containment operation;
- Compliance with international animal biosafety laboratory (ABSL) construction codes.
Solutions
- Airtight trough transfer structure: the liquid-sealed/gasket-sealed trough structure enables safe material transfer with stable airtightness and no aerosol escape;
- Double-door interlock: reliable interlock logic prevents both doors from opening simultaneously, avoiding direct air convection between zones;
- Stable pressure differential isolation: maintains correct differential pressure to support the laboratory protection level;
- Corrosion-resistant stainless steel: high-grade stainless steel with seamless one-piece welding is suited to long-term operation in animal biosafety environments;
- Complete qualification documents: factory inspection reports and technical documents are provided to meet overseas laboratory factory audit requirements.
Project Outcomes
The trough pass box delivered has been installed and is operating stably in the overseas P3 animal biosafety laboratory. The equipment reliably achieves airtight transfer and stable pressure differential isolation, effectively blocking pathogenic aerosol escape and supporting the safe operation of the high-containment animal biosafety laboratory. All equipment met performance requirements and passed customer acceptance, conforming to international animal biosafety laboratory codes.