Home > Products > Pharmaceutical Industry > Bag-In /Bag-Out Exhaust Air Housing
Return to list

Bag-In /Bag-Out Exhaust Air Housing

The Bag-In /Bag-Out Exhaust Air Housing (BIBO) is an exhaust filtration device used in clean areas such as biosafety laboratories, nuclear industries, pharmaceutical plants, and negative pressure wards. Utilizing a bag-in/bag-out filter replacement method, it effectively isolates radioactive gases, pathogens, and other toxic and harmful pollutants, preventing secondary air pollution and ensuring operator safety.

Introduction

Bag-In /Bag-Out Exhaust Air Housing
The Bag-In /Bag-Out Exhaust Air Housing is an exhaust filtration device that uses a bag-in/bag-out filter replacement method. It can effectively isolate radioactive gases, pathogens, and other toxic and harmful pollutants, effectively preventing secondary air pollution and ensuring the safety of operators.

Side exhaust BIBO internal structure
Side exhaust BIBO

Application areas

This exhaust filter section is used in clean areas such as high-level biosafety laboratories, nuclear industry, pharmaceutical plants, and negative pressure wards. It is installed on the side wall. The recessed installation method makes the air intake surface flush with the wall, which is more aesthetically pleasing, occupies less space, and is easy to operate.

Product Advantages

The bag-in, bag-out filter replacement method is safer.

The enclosure is constructed with 2mm thick SUS304 stainless steel and fully welded, providing excellent corrosion resistance.

The rational structural design ensures that the enclosure has good airtightness, meeting the test requirements of ASME N510 and JG/T 497-2016 "Exhaust Air High-Efficiency Filtration Devices".

Side-wall installation saves space and provides a neat and aesthetically pleasing appearance.

It can perform online leak detection tests on filters, which is simple to operate and more accurate;

Real-time monitoring of the pressure difference across the filter allows for a direct assessment of the filter's lifespan.

Standard configuration includes a high-efficiency filter; optional ultra-high-efficiency filter or PTFE filter.

It can be configured with multi-stage filtration sections and activated carbon filtration sections;

Optional in-situ disinfection function;

A biosafety shut-off valve can be optionally installed.

Technical Specifications

ModelSingle-Layer Dual FiltrationPrimary/Advanced FiltrationMedium/Advanced/Activated Carbon Filtration
Dimensions (WxHxD)740x1800x455 mm740x2040x760mm740x2090x760mm
Max. Airflow850CMH/500 CFM1700 CMH/1000 CFM3400 CMH/2000 CFM
HEPA SectionH14 (EN1822)H14 (EN1822)H14 (EN1822)
305x610x292 mm-1 pes610x610x292 mm-1 pcs610x610x292 mm-1 pcs
Pre/Medium SectionN.AG4F8
Activated Carbon SectionN.AN.AVOC
MaterialSUS 304/Cold-rolled Steel (Single Guide)
PAO PortAccessories: 0-750 Pa
Pressure Gauge/SensorAccessories
InstrumentationAccessories
Biosafety Advisory UnitAccessories
Exhaust PortAccessories
HEPA Filter ScanAccessories: Auto Handwash Station

Note: Dimensions are standard or customizable.