Bag-In / Bag-Out Housing (BIBO)
Bag-In / Bag-Out Housing are commonly used duct-type high-efficiency exhaust devices in the pharmaceutical industry and biosafety laboratories.
Series:Ku Ba
Certified with CNAS and CMA
- Third-party performance testing available
- Modular design, easy to ship
- Zero-contact safe replacement of filter
- Single/Multi filter design
Introduction
Bag-In / Bag-Out Housing (BIBO) are a type of safety filtration system typically connected to an exhaust system to prevent the leakage of harmful pollutants. The fully enclosed bag-in-bag-out design provides a safe and reliable method for filter replacement, effectively preventing secondary air pollution.

Main application areas: Pharmaceutical engineering (exhaust ventilation in vaccine production workshops, supply and exhaust ventilation in animal facilities of vaccine workshops, supply and exhaust ventilation in hormone and cytokine drug production workshops, exhaust ventilation in high-activity chemical production workshops, exhaust ventilation in anti-cancer preparation production workshops, supply and exhaust ventilation for isolation equipment), supply and exhaust ventilation for biosafety laboratories, exhaust ventilation for hospital isolation areas, industrial chemical gas emissions, nuclear power plants and fuel processing facilities, animal disease laboratories, and toxic waste isolation plants.
Industrial research and military facilities that handle chemical, biological, radioactive, or carcinogenic substances, Biomedical research and genetic engineering facilities pharmaceutical laboratories.
Airtightness (Third-party performance testing available)
The enclosure is constructed using a fully welded integral process, with a standard pressure resistance of ±3 kPa. Before leaving the factory, it undergoes an airtightness test at a pressure of no less than 2.5 kPa. It meets the requirements of GB 50346-2011 and JG/T 497-2016 and has obtained third-party testing certificates.
Protective sealed bag:
Each access door of the Bag-In /Bag-Out Housing is equipped with a protective bag, approximately 2 meters long, and includes a full set of straps and safety belts. The premium model comes with two internal gloves for ease of handling. Filter replacement is performed inside the protective bag, preventing gas inside the box from contacting the outside environment, thus protecting the safety of operators and the environment.
Installation method
The standard installation method is horizontal installation, but vertical installation or other installation methods can be selected depending on the site conditions.
Connecting equipment in series can extend the residence time of gas inside the chamber.
A rain shelter can be installed when installing outdoors.
Special note: Please specify the functional sections and material requirements before ordering.

The standard installation method for the BIBO Bag-In /Bag-Out Housing is horizontal. Vertical installation or other installation methods can be customized.
Single or multiple filter stages
Single-stage filtration systems consist of only one HEPA filter, while multi-stage filtration systems can add pre- and medium-efficiency filters, chemical filters, activated carbon filters, or dual HEPA filters. The filtration chamber can be designed to accommodate different needs. When a longer residence time of the gas within the chamber is required, the filters can be installed in series.
Terminal HEPA filter: Bag-In /Bag-Out Housing, designed according to standard 610*610*292mm HEPA filter or activated carbon filter. Box-type HEPA filters can achieve an airflow of up to 4000 CMH. Custom-made filters are also available in special sizes to meet site requirements.
Optional accessories
- A shut-off valve can separate and block airflow.
- The PAO scan segment is used for filter leak testing.
- Differential pressure gauge/differential pressure sensor monitors the pressure difference before and after the filter.
- The instrument protection system protects personnel safety when replacing/calibrating instruments.
- The disinfection port allows for disinfection of the inside of the container.
- The variable diameter interface allows for connection to air supply and exhaust ducts of different sizes.
Technical Specifications
| Item | KuBa-HNH | KuBa-1CH | KuBa-4CH |
|---|---|---|---|
| External dimensions (H×W×D) | 708×403×540 mm | 708×708×834 mm | 1416×1416×834 mm |
| Maximum air volume | 1700 CMH / 1000 CFM | 3400 CMH / 2000 CFM | 13600 CMH / 8000 CFM |
| HEPA filtration section | H14 (EN1822) | H14 (EN1822) | H14 (EN1822) |
| HEPA filter dimensions and quantity | 305×610×292 mm-1 pcs | 610×610×292mm mm-1 pcs | 610×610×292mm-4 pcs |
| Pre/medium filtration section | N.A | G4 | F8 |
| Activated carbon section | N.A | N.A | VOC |
| Casing material | Cold-rolled steel (electrostatic spray coating) / SUS 304 | Cold-rolled steel (electrostatic spray coating) / SUS 304 | Cold-rolled steel (electrostatic spray coating) / SUS 304 |
| PAO sampling port | SUS 304,ф10mm | SUS 304,ф10mm | SUS 304,ф10mm |
| Differential pressure gauge/sensor | Optional accessory, 0~750 Pa | Optional accessory, 0~750 Pa | Optional accessory, 0~750 Pa |
| HEPA filter PAO scan section | Optional accessory, manual or automatic | Optional accessory, manual or automatic | Optional accessory, manual or automatic |
Note:Dimensions and functions can be customized. Please specify required functional stages and material requirements when ordering.